The short-tube Rotameter is used for measurement of flow rates of liquids and gases. Its special application is in troubled, opaque or aggressive mediums. The instrument is mounted in a vertical pipeline with flow direction upwards.

 

Inside the special shaped conicmetal tube, a float is guided concentrically. The position of this float is magnetically transmitted to the indicator. The indicators are exchangeable without influence on the accuracy.

FEATURES of Yokogawa RAMC12-A1SS-8111-T90NNN/IE1 RAMC12 Rotameters RAMC12 Flowmeters Germany Original

 

• Different process connections like flanges according to EN and ASME

• All wetted parts in stainless steel or PTFE

• Maximum flow 0.025 - 130 m³/h water resp. 0.75 - 1400 m³/h air (20 °C/ 1.013 bar abs)

• Measuring accuracy acc. Directive VDI/VDE 3513 sheet 2(qG=50 %)

• Float damping to avoid float bouncing with gas applications

• Optional heat tracing (with steam or fluid heat carrier)

• Indicator in stainless steel, aluminium, protection class IP66/67

• Local indicator without additional power supply

• Microprocessor controlled transmitter with 24 V, 115 V or 230 V power supply

• Intrinsically safe version (Ex-i): ATEX, IECEx, FM (US/C),NEPSI, PESO, EAC, INMETRO

• Flame proof version (Ex-d): ATEX, IECEx, NEPSI, PESO,KOSHA, EAC, TS

• Dust explosion proof: ATEX, IECEx, NEPSI, PESO, KOSHA

• Ex for non- electrical RAMC: ATEX, EAC

• FMEDA report available for SIL application

• Limit switches, also available as “Fail Safe” version

 

Yokogawa RAMC12-A1SS-8111-T90NNN/IE1 RAMC12 Rotameters RAMC12 Flowmeters Germany Original
 

At first glance the instrument looks impressive with its all stainless steel design. A closer look reveals a unique patented "float blockage" detection system. Operational safety is of the utmost importance in any flowmeter, and the RAMC is no exception – wetted parts are available in a variety of materials, and intrinsically safe utputs are available as an option.

 

If you value flexibility in a flowmeter – from the measurement of air to highly aggressive liquids – in situ replacement of the indicator without loss of performance – and the interchangeability of floats – then the RAMC is the right choice for you.

 

The RAMC combines all the advantages of the variable area principle with robust design, reliable measurement, with or without power, HART® or Profibus PA, culminating in a truly universal flowmeter for gases, liquids and steam applications. 

 

 

Characteristics of Yokogawa RAMC12-A1SS-8111-T90NNN/IE1 RAMC12 Rotameters RAMC12 Flowmeters Germany Original

 

• Flow indication (totalize, actual, percent)

• Indication of different volume- and mass flow units

• Second (manual) calibration storing

• Patented float blocking indication function

• Signal output damping

• Error message indication

• Temperature measurement in the electronic transmitter

• HART5/7-Communication

• Profibus PA-Communication

 

Specification of Yokogawa RAMC12-A1SS-8111-T90NNN/IE1 RAMC12 Rotameters RAMC12 Flowmeters Germany Original

 

For Pipe Sizes

DN 15 to DN 25 (1/4” – 1“)

Process Connections

Flange, threaded

Measuring Range

Water 20 °C: 2,5 l/h to 130 m³/h
Air 20 °C 1 bar abs.: 75 l/h to 1400 m³/h

Wetted Parts Material

1.4404 (AISI 316L), PTFE-lining Hastelloy,
Monel and Titanium on request

Process Temperature

-200 °C to + 370 °C

Process Pressure

100 bar, higher pressures on request

Ambient Temperature

-40 °C to 100 °C

Accuracy acc. VDE/VDI 3513-2(qG =50%)

1,6 %

Ex-approvals

ATEX, FM(US,C), NEPSI

Signal Outputs

Analog 0-20mA / 4-20mA, pulse output

Communication

HART, Profibus PA

Power Supply

24 V DC 2-wire, 24 V DC 3-wire, 115 V AC 4-wire, 230 V AC 4-wire

Degree of Protection

IP66/IP67

Suitable for Applications acc. IEC 61508 and Machinery Directive ISO 13849

Yes

Additional Features

Patented float blockage detection system
Limit switches for low/high alarms
Float damping for gas applications
Flame proof/dust proof housing
Heat tracing and temperature spacer

 


Yokogawa RAMC12-A1SS-8111-T90NNN/IE1 RAMC12 Rotameters RAMC12 Flowmeters Germany Original

Model Suffix code Description Restrictions
RAMC01   Size DN 15 (½ inch) for D4, D6, A1, A2, A3, T4, R4, T6, G6
RAMC23 Size DN 20 (¾ inch) for D4, D6, A1, A2, A3, T4, R4, T6, G6
RAMC02 Size DN 25 (1 inch) for D4, D6, A1, A2, A3, S2, S4, S5, T4,R4, T6, G6
RAMC03 Size DN 32 (1¼ inch) for D4, D6, A1, A2, A3, S4, T6, G6
RAMC04 Size DN 40 (1½ inch) for D4, D6, A1, A2, A3, S4, S5, T6, G6
RAMC05 Size DN 50 (2 inch) for D4, D5, D6, A1, A2, A3, S2, S4,T4, R4
RAMC06 Size DN 65 (2½ inch) for D4, D5, A1, A2, A3, S2, S4, T4, R4,T6, G6
RAMC08 Size DN 80 (3 inch) for D4, D5, A1, A2, A3, S2, S4
RAMC09 3½ inch for A1, A2
RAMC10 Size DN 100 (4 inch) for D2, D4, A1, A2, S4, S4
RAMC12 Size DN 125 (5 inch) for D2, A1, A2, S2
RAMC15 Size DN 150 (6 inch) for D2, A1, A2
RAMCNN Without measuring tube  
       
 

 
 
Ordering Models of Yokogawa RAMC12-A1SS-8111-T90NNN/IE1 RAMC12 Rotameters RAMC12 Flowmeters Germany Original
 
Yokogawa RAMC Metal Short-stroke Rotameter
Yokogawa RAMC Metal Short-stroke Rotameter RAMC01
Yokogawa RAMC Metal Short-stroke Rotameter RAMC23
Yokogawa RAMC Metal Short-stroke Rotameter RAMC02
Yokogawa RAMC Metal Short-stroke Rotameter RAMC03
Yokogawa RAMC Metal Short-stroke Rotameter RAMC04
Yokogawa RAMC Metal Short-stroke Rotameter RAMC05
Yokogawa RAMC Metal Short-stroke Rotameter RAMC06
Yokogawa RAMC Metal Short-stroke Rotameter RAMC08
Yokogawa RAMC Metal Short-stroke Rotameter RAMC09
Yokogawa RAMC Metal Short-stroke Rotameter RAMC10
Yokogawa RAMC Metal Short-stroke Rotameter RAMC12
Yokogawa RAMC Metal Short-stroke Rotameter RAMC15

 
Ordering Codes of Yokogawa RAMC12-A1SS-8111-T90NNN/IE1 RAMC12 Rotameters RAMC12 Flowmeters Germany Original
 
RAMC01-A2SS-44S0-E90424/SD/KS1/BG/P6/P2
RAMC05-A1SS-71L5-T90NNN
RAMC05-D4SS-72S5-E90424
RAMC05-D4SS-72L5-E90424
RAMC05-D4SS-72L5-T90NNN
RAMC05-A2SS-63S2-T90NNN/B1/P6
RAMC02-A1SS-64V2-T90NNN/A13/B1/BG/P6/PP/lE1
RAMC02-A1SS-64V2-T90NNN/A13/B1/BG/P6/PP/lE1
RAMC02-A1SS-64M2-T90NNN/A13/B1/BG/K7/KS1/P6/PP/SD/
RAMC02-A1SS-51S0-T90NNN/A13/B1/BG/P6/PP/SD/IE1
RAMC02-A1SS-51S0-T90NNN/A13/B1/BG/P6/PP/SD/IE1
RAMC02-A1SS-63L2-T90NNN/A13/B1/BG/K7/KS1/P6/PP/SD/
RAMC02-A1SS-54L1-T90NNN/A13/B1/BG/P6/PP/IE1
RAMC02-A1SS-63L2-T90NNN/A13/B1/BG/K6/KS1/P6/PP/W4E
RAMC02-A1SS-53M1-H90424/A13/B1/BG/KS1/P6/PP/SD/IE1
RAMC02-A1SS-64L2-H90424/A13/B1/BG/KS1/P6/PP/IE1
RAMC02-A1SS-57L1-T90NNN/A13/B1/BG/K7/KS1/P6/PP/SD/
RAMC02-A1SS-61M1-T90NNN/A13/B1/BG/K6/KS1/P6/PP/W4E
RAMC02-T6SS-62L1-T91434 RAMC02-T6SS-62L1-T91434
RAMC02-S4SS-62V2-T90424/NS1/BG/IE1
RAMC02-S2SS-54L1-E90424/SD/ID2/IE2
RAMC02-S2SS-54L1-E90424/SD/ID2
RAMC02-D4SS-64V2-T90NNN/BG
RAMC02-D4SS-64V2-H91424/NF1
RAMC02-D4SS-64S2-E66424/IE1
RAMC02-D4SS-63V2-H91424/NF1
RAMC02-D4SS-63M2-E90424/NS1
RAMC02-D4SS-62L1-E90424/SD/IE1
RAMC02-D4SS-53L1-H90424/SD
RAMC02-D4SS-47S0-E90424/SD/IE1
RAMC02-D4SS-43S0-T90NNN/A13/BG/K6/KS1/P6/SD
RAMC01-A1SS-53L1-T90NNN/BG/P6
RAMC01-A1SS-53S1-T90NNN/B0/K1/P6/IE1
RAMC01-A1SS-53S1-T90NNN/BG/P6
RAMC01-A1SS-53S1-T90NNN/BG/P6/IE1
RAMC01-A2SS-53L1-T90NNN/B1/P6
RAMC01-A2SS-54V1-T90NNN/K6/KS1/P6/PP/IE1
RAMC01-A2SS-62V1-T90NNN/K6/KS1/P6/PP/IE1
RAMC01-D4SS-43S0-H91424/KF1
RAMC01-T4SS-57M1-T90NNN/K9/KS1
RAMC01-D4SS-43S0-H90424/BG/KS1/P3/SD

Yokogawa RAMC12-A1SS-8111-T90NNN/IE1 RAMC12 Rotameters RAMC12 Flowmeters Germany Original
 
RAMC01-D4SS-54S1-H90424*D/P6/IE1
RAMC01-D4SS-54S1-H90424*D/XE/P6/IE1
RAMC01-A2SS-54V1-T90NNN/K6/KS1/P6/PP/IE1
RAMC08-A2SS-74V8-E91434
RAMC05-A2SS-72S5-E91434
RAMC04-A2SS-72SS-E91434
RAMC02-A2SS-72S5-E91434
RAMC06-A2SS-72S5-E91434
RAMC01-T4SS-57L1-T91NNN
RAMC01-T4SS-51S0-T91NNN
RAMC02-A2SS-53L1-T91NNN
RAMC02-T4SS-57L1-T91NNN
RAMC02-T4SS-51S0-T91NNN
RAMC05-D4SS72V5H90424-A13/B1/IE1
RAMC08-D4SS-74L8-E90424
RAMC01-D4SS-62M1-E90424


Yokogawa RAMC12-A1SS-8111-T90NNN/IE1 RAMC12 Rotameters RAMC12 Flowmeters Germany Original

RAMC05-D4SS-72V5-H90424
RAMC02-D4SS-64S2-T90NNN/BG/SD/IE1/ID1
RAMC02-D4SS-63L2-T90NNN/BG/SD/IE1/ID1
RAMC08-D4SS-74L8-NNN
RAMC01-D4SS-62M1-NNN
RAMC08-D4SS-74L8-E90424
RAMC01-D4SS-62M1-E90424
RAMC01-A2SS-53L1-T90NNN/B1/P6
RAMC02-A1SS-62L1-H91424/A13/A14/BG/P3
RAMC08-A1SS-77V8-T90NNN/K1/P3/P6
RAMC02-D4SS-64S2-T90NNN/BG/SD/PP/P2
RAMC02-D4SS-63L2-T90NNN/BG/SD/PP/P2
RAMC02-A1-SS-63S2-E-90-424/SD/KS2
RAMC04-A1-SS-63S2-E-90-424/SD/KS2
RAMC02-A1SS-62L1-T90NNN*D/B0/K1/P6/IE1
RAMC02-D4SS-64S2-H90424/A13/B1/SD
RAMC01-A2SS-4450-E90424/A13/SD/BG/P6/P2
RAMC01-A2SS-44S0-E90424/SD/BG/P6/P2
RAMC10-A1SS-77L8-T90NNN
RAMC02-D4SS-62S1-E65244/IEI
RAMC06-S4SS-71S5-E90424/BG/H3/P6/IE1
RAMC02-D4SS-62S1-E65244/IEI
RAMC10-A1SS-8111-E91424/BG/KS1
RAMC01-A1SS-54M1-E90424

Yokogawa RAMC12-A1SS-8111-T90NNN/IE1 RAMC12 Rotameters RAMC12 Flowmeters Germany Original

 
We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.

We mainly supply Yokogawa, Emerson, Rosemount, Fisher, Honeywell, Siemens, ABB, FLUKE, Endress+Hauser, Schneider Electric, Pepperl+Fuchs, MTL, Rockwell(Allen Bradley), Hirschmann, Eaton, Moeller, FUJI, Omron, Yaskawa, Norgren, CHINT, Hach, Weidmuller, Phoenix, SMC, Testo, ASCO, Parker, Mitsubishi, Festo, GE, CISCO, Auma, IFM, GM, Turck, Bently Nevada, MOXA, Krohne, Foxboro and so on.
 
 
Why choose us?
 
1. 100% original product, 100% quality assurance.
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
 
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
 
3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex,TNT and EMS etc., the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.
 
Packaging: 
Imported with original packaging or standard export packing.Customize design is acceptable.
 
Contact:
 
HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com   Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat) 

Previous:Yokogawa RAMC08-D4SS-74V8-T90NNN/IE1 RAMC08 Flowmeters RAMC0 Next:Yokogawa DY050-FBLBA2-4N/SCT/NS1 DY050 Vortex Flowmeters DY0
 Footer begin -->